THA: Highly crosslinked polyethylene reduces wear but has no effect on other outcomes

Vol: 2| Issue: 4| Number:143| ISSN#: 2564-2537
Study Type:Therapy
OE Level Evidence:2
Journal Level of Evidence:N/A

Highly Crosslinked Polyethylene Does Not Reduce Aseptic Loosening in Cemented THA 10-year: Findings of a Randomized Study

Clin Orthop Relat Res. 2012 Nov;470(11):3083-93. doi: 10.1007/s11999-012-2400-x

Contributing Authors:
PE Johanson G Digas P Herberts J Thanner J Kärrholm

Did you know you're eligible to earn 0.5 CME credits for reading this report? Click Here

Synopsis

60 patients (61 hips) undergoing unilateral total hip arthroplasty (THA) were randomized to receive polyethylene (PE) or highly crosslinked polyethylene (XLPE) cemented cups combined with a cemented stem. Over 10 years, the XLPE cups demonstrated significantly reduced three-dimensional wear than the PE cups. The XLPE group also tended to have superior stem fixation than the PE group. However, ther...

CME Image

Did you know that you’re eligible to earn 0.5 CME credits for reading this report!

LEARN MORE

Join the Conversation

Please Login or Join to leave comments.

Learn about our AI Driven
High Impact Search Feature

High Impact Icon

Our AI driven High Impact metric calculates the impact an article will have by considering both the publishing journal and the content of the article itself. Built using the latest advances in natural language processing, OE High Impact predicts an article’s future number of citations better than impact factor alone.

Continue